Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 30

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 29 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

29

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault #

Fault Legend

Description

12B66

76646

11110

GEAR Input

A GEAR function block has detected
a value of ‘0’ for its
“InputGear_Denominator” input.

No

Yes

Yes

Minor

FB_se

tup

Ensure that the GEAR function block
input(s) “InputGear_Denominator” is not
set to zero.

12B67

76647

11111

POSR_0
Input

A POSR_0 function block has
calculated an out of range value for
its “DancerOut” output.
“DancerOut” is the “DancerSignal”
modified by a SPAN and ZERO
adjustments provided by
corresponding the POSR_1 function
block. “DancerOut” is a per-unit
number and this fault is declared if
“DancerOut” calculates as less than
-0.1 or greater than +1.1.

No

Yes

Yes

Minor

FB_se

tup

Ensure that the DancerSignal of the
corresponding POSR_1 function block
has been calibrated. Ensure that the
dancer feedback mechanism has not
moved. The dancer signal in the
corresponding POSR_1 function block
may need recalibration.