Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 26

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 25 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

25

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault #

Fault Legend

Description

12B06

76550

11014

NDelay Input

An NDelay function block has
detected that its “Delays” input is
outside the valid range of 1 to 500.

No

Yes

Yes

Minor

FB_se

tup

Review the NDelay function blocks to
ensure all “Delays” inputs are within the
range of 1 to 500.

12B07

76551

11015

REFQ Input

A REFQ function block has detected
a “CascadeNumber” input >
“MaxCascadeNumber” input, or,
“MaxCascadeNumber” input does
not fall within a valid range of 1
through 255.

No

Yes

Yes

Minor

FB_se

tup

Ensure the REFQ function block has a
“CascadeNumber” input less than or
equal to “MaxCascadeNumber” input.
Ensure “MaxCascadeNumber” input
ranges from 1 to 255.

12B08

76552

11016

DIAM_2
Input

A DIAM_2 block has detected an out
of range value on one or more of its
inputs labeled RatedLineSpeed,
S_RPM_AT_M_RPM,
MaxDiameter, MinDiameter, or
NumberCalculation.

No

Yes

Yes

Minor

FB_se

tup

Ensure the DIAM_2 block has the proper
values at its inputs as follows:
RatedLineSpeed > 0,
S_RPM_AT_M_RPM > 0,
MinDiameter > 2 inches, or 5 cm,
MinDiameter <= MaxDiameter <= 99
inches, or 200 cm,
0 <= NumberCalculation <= 255.

12B09

76553

11017

INRT_1 Input

An INRT_1 block has detected a
value of 0 on the RatedHorsepower
input.

No

Yes

Yes

Minor

FB_se

tup

Ensure the INRT_1 block has a positive,
non-zero value for its RatedHorsepower
input.

12B0A

76554

11018

CTCW_0
Input

A CTCW_0 block has detected a
value of 0 on its Diameter input

No

Yes

Yes

Minor

FB_se

tup

Ensure the CTCW_0 block has a
positive, non-zero value for its Diameter
input.

12B0B

76555

11019

CTCW_1
Input

A CTCW_1 block has detected a
value of 0 on either the Horsepower
or the S_RPM_AT_M_RPM inputs.

No

Yes

Yes

Minor

FB_se

tup

Ensure that the CTCW_1 block has
positive, non-zero values for both the
Horsepower and S_RPM_AT_M_RPM
inputs.

Advertising