Displayed Fault No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

Fault Legend

Description

2C

44

Bad Upper
Bound

Index into an internal array has
exceeded the upper bounds.

No

Yes

Yes

Minor

Minor

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists..

2D

45

Invalid
DateTime

Invalid date or time has been
specified.

No

Yes

Yes

Minor

Minor

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.

2E

46

Invalid P-code

Invalid P-code instruction

Yes

Yes

Yes

Critical

Critical

and

Major

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists..

2F

47

Not used

7FF7

32759

Not used

7FF8

32760

User Task
Hung

Attempts to terminate a Task, or
remove it completely from the
processing queue have failed.

Yes

Yes

Yes

Critical

Critical

and

Major

Application program may be overburdened –
reduce amount of logic placed in fast Tasks
(15ms or faster) to slow Tasks (30ms or slower).
This may include reducing number of Program
Units and/or program elements.

Advertising