Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 23

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 22 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

22

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault #

Fault Legend

Description

12AFB

76539

11003

Illegal Input

The input to a block has an
inappropriate input. The blocks
declaring this are CAVE, DAVE,
LDelay, NDelay, REFQ, TENR_1,
POSR_1, and POSR_2. These
function blocks expect parameter
inputs within a specified number
range.

( Note: this fault applies to
MAG_CPB libraries V1.8 and
older. )

Yes

Yes

Yes

Minor

FB_se

tup

Refer to block description Help in Smart
Trac AC1 Workstation software. Obey
these limits:
Samples for CAVE = 1 to 500;
Samples for DAVE = 1 to 1000;
Delays for LDelay = 1 to 500;
Delays for NDelay = 1 to 500;
REFQ CascadeNumber = 1 to
MaxCascadeNumber;
TENR_1 needs inputs for Webwidth,
WebThickness and TensionZoneLength.
POSR_1 Roll_Diameter > 1;
For POSR_2, all of these must be > 0:
RatedLineSpd, R1_Factor, R2_Factor,
RatedDancerStorage,
S_RPM_At_M_RPM,
POSR_0_ScanTime.

12AFC

76540

11004

PG Illegal
Port

The port setting to the
PG_ANALOG_IN, PG_DELTA_P,
or PG_TACH block is not one of the
legal values of 0, 1, 2 or 3.

Yes

Yes

Yes

Minor

Major

Port number is used to identify the PG
card. Note: older versions of the PG card
had legal values of 0 through 3. Newer
PG cards have only one port setting. Use
PortNumber = 1.

12AFD

76541

11005

PG Illegal
Chan

The channel input setting to the
PG_TACH or PG_ANALOG_IN
block is not one of the legal values
of 0 or 1.

Yes

Yes

Yes

Minor

Major

Use only channel 0 or channel 1. All
other values will cause this fault.
Reference drive schematic to set
correctly.

Advertising