Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 46

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 45 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

45

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault

No
.

Fault Legend

Description

1754B

95563

30027

Output Pha Loss

LF – Drive output has open phase.

Yes

Yes

Yes

Minor

Major

Check wiring between inverter and
motor. Note: inverter parameter L8-
07 = 1 enables this fault.

1754C

95564

30028

Not used

1754D

95565

30029

Oper Disconnect

OPR – Operator disconnected.
Digital operator has been
disconnected from drive while in
Run mode.

Yes

Yes

Yes

Minor

Major

Reconnect digital operator to inverter
or disable this fault by setting
inverter parameter o2-06 = 0.

1754E

95566

30030

EPROM R/W Err

ERR – EPROM write-in fault.
Attempt to write to nonvolatile
memory has failed.

Yes

Yes

Yes

Minor

Major

Cycle power and then attempt to
initialize. If fault persists, Smart Trac
AC1 inverter card is bad.

1754F

95567

30031

Not used

17550

95568

30032

Memobus Com Err

CE – Communication fault. Control
data was not received for 2 seconds
after initial communication.

Yes

Yes

Yes

Minor

Major

Check validity of Smart Trac AC1
CPU card firmware and application
program. This fault is declared only
if H5-04= 0, 1 or 2 and H5-05= 1.

17551

95569

30033

Option Com Err

BUS – Communication fault.
Communication fault while drive is
set for Run Command and/or
Frequency Reference from Smart
Trac AC1 CPU card.

Yes

Yes

Yes

Minor

Major

Check validity of Smart Trac AC1
CPU card firmware and application
program. Ensure inverter parameters
B1-01, B1-02 = 3. Note: The input
labeled ‘Major’ is set only if inverter
parameter F9-06

3.

Advertising