Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 27

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 26 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

26

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault #

Fault Legend

Description

12B0C

76556

11020

PG_TACH
Input

A PG_TACH or PG_TACH2 block
has detected a value of 0 on the
TachCounts or RatedSpeed inputs.

No

Yes

Yes

Minor

FB_se

tup

Ensure the PG_TACH or PG_TACH2
block has non-zero values for the
TachCounts and RatedSpeed inputs.

12B0D

to

12B5B

76557 to

76635

11021

to

11099

Not Used

12B5C

76636

11100

Tach Loss

The TMON block has detected a
tachometer (encoder) loss.

Yes

Yes

Yes

Minor

Major

Check wiring from encoder to PG card.
Tach loss occurs when AuxSpeedSense
> (AuxSenseLevel / 100) and
TachometerInput < (TachSenseLevel /
100).

12B5D

76637

11101

Reverse Tach
Flt

The TMON block has detected a
reversed tachometer (encoder)
connection.

Yes

Yes

Yes

Minor

Major

Change wiring from encoder to PG card.
Declared when AuxSpeedSense >
(AuxSenseLevel / 100) AND
(ReferenceInput > 0 and
TachometerInput < 0) OR
(ReferenceInput < 0 and
TachometerInput > 0).

12B5E

76638

11102

Fwd
Overspeed

The TMON block has detected an
overspeed condition in the forward
direction.

Yes

Yes

Yes

Minor

Major

Motor speed has exceeded the forward
setpoint: TachometerInput >
(FwdOverspeedLimit / 100). Reduce
commanded speed or load if runaway
condition exists.

Advertising