Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 35

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 34 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

34

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault #

Fault Legend

Description

14EEF

85743

20207

LAN Rem Out
Time

Remote No Output
Command Fault – This
message is sent from a
remote I/O node when
it does not receive an
output command LAN
message from a Smart
Trac AC1 drive, that
has allocated one or
more outputs, within
the prescribed time.

No

Yes

Yes

Minor

Minor

Possibility that a supporting Task in Smart
Trac AC1 has encountered a fault.

14EF0

85744

20208

LAN Rem Num
In

Numeric Input
Request Fault – This
message is sent from
the remote I/O node to
the Smart Trac AC1
drive when the remote
I/O node cannot
provide a digital
numeric input to the
drive for reasons other
than LAN failure.

No

Yes

Yes

Minor

Minor

A typical reason for this condition might be
that there is no digital numeric input module
located at the given channel/subchannel.

Advertising