Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 36

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 35 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

35

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault #

Fault Legend

Description

14EF1

85745

20209

LAN Rem Logic
In

Logic Input Request
Fault – This message
is sent from the remote
I/O node to the Smart
Trac AC1 drive when
the remote I/O node
cannot provide a
logical input for
reasons other than
LAN failure.

No

Yes

Yes

Minor

Minor

A typical reason for this condition might be
there is no logic I/O channel located at the
given channel.

14EF2

85746

20210

LAN Rem Num
Out

Numeric Output
Allocation Fault – The
requested numeric
output allocation could
not take place because
of an allocation
conflict with another
device or the absence
of the device(s) being
requested.

No

Yes

Yes

Minor

Minor

Check for duplicate LAN node, channel and
subchannel in drive programs. Possible
incorrect setting of node channel or
subchannel at remote device.