Drivers, Dpram driver, Smart trac – Yaskawa SmartTrac Fault Tables User Manual

Page 31: Faults.doc

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 30 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

30

5. Drivers

5.1 DPRAM Driver
The following section details fault numbers assigned to Dual Port RAM.

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault #

Fault Legend

Description

14E20

85536

20000

DPRAM HS Resp

High Speed response
handshake fault between the
Smart Trac AC1 CPU card
and the inverter control card.

No

Yes

Yes

Minor

Minor

High Speed data such as torque reference
and motor speed cannot be obtained from
the inverter card. Recycle drive power. If
problem persists, consult the factory.

14E21

85537

20001

DPRAM HS Cmd

High Speed command
handshake fault between the
Smart Trac AC1 CPU card
and the inverter control card.

Yes

Yes

Yes

Minor

Major

High Speed command information such as
Run/Stop cannot be sent to the inverter
card. Drive must be stopped by externally-
wired E-stop. Recycle drive power. If
problem persists, consult the factory.

14E22

85538

20002

DPRAM Response

DPRAM response handshake
fault between the Smart Trac
AC1 CPU card and the
inverter control card.

No

Yes

Yes

Minor

Minor

Inverter parameters such as ‘Accel Time 1’
cannot be obtained from the inverter card.
Recycle drive power. If problem persists,
consult the factory.

14E23

85539

20003

DPRAM Command

DPRAM command
handshake fault between the
Smart Trac AC1 CPU card
and the inverter control card.

No

Yes

Yes

Minor

Minor

Cannot send parameters values from Smart
Trac drive’s CPU card to inverter card.
Recycle drive power. If problem persists,
consult the factory. Note: there are some
critical parameters that cannot be changed
during Run.