Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

18

Displayed Fault No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

Fault Legend

Description

7FF9

32761

No Startup FB

No startup function block was
configured for a user task.

Yes

Yes

Yes

Critical

Critical

and

Major

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists..

7FFA

32762

Breakpoint Set

Breakpoint encountered in
program. Not really a fault but
used for debug purposes.

Yes

Yes

Yes

N/A

Critical

and

Major

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.

7FFB

32763

Bad Offset
Range

Attempt to address data within
memory is out of range.

Yes

Yes

Yes

Critical

Critical

and

Major

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.

7FFC

32764

Task Overrun

Task has taken too long to
complete. Applies to Cyclic and
IoSync Tasks only.

Yes

Yes

Yes

Critical

Critical

and

Major

Application program may be overburdened –
reduce amount of logic placed in fast Tasks
(15ms or faster) to slow Tasks (30ms or slower).
This may include reducing number of Program
Units and/or program elements.

7FFD

32765

Restart Failed

A request to have a Task change
from stop to start mode has
failed.

Yes

Yes

Yes

Critical

Critical

and

Major

Check for valid installed hardware. For example,
if using the STLAN driver, make sure an
ARCNET card is part of the Smart Trac card
stack.