Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 14

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 13 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

13

Displayed Fault No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

Fault Legend

Description

19

25

Float Error

Floating point error: an unknown
float error, which is detected
only if all other floating point
errors have not triggered a fault
(underflow, overflow, float
invalid).

No

Yes

Yes

Minor

Minor

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.

1A

26

Fstack
Overflow

Float stack overflow. Float
pointer has gone past the end of
the float stack.

Yes

Yes

Yes

Minor

Major

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.

1B

27

Fstack
Underflow

Float stack underflow. Float
pointer has preceded the
beginning of the float stack.

Yes

Yes

Yes

Minor

Major

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.

1C

28

Bad Operand

Based on the operand’s mode,
operand address is invalid.

Yes

Yes

Yes

Major

Major

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.

Advertising