Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 42

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 41 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

41

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault

No
.

Fault Legend

Description

1753A

95546

30010

Motor Overloaded

OL1 – Motor overload. Protects the
motor. Motor thermal overload
protection has tripped. Inverter
parameter L1-02 has been exceeded
(initial value: 150% for 60 sec.).

Yes

Yes

Yes

Minor

Major

Major fault is declared if L1-01 = 1.
Load may be too large. Check drive
capacity (inverter parameter o2-04)
for correct factory setting. Check for
proper setting of electronic thermal
overload setting: inverter parameters
E1-02, E2-01, L1-02. Try
disconnecting motor wiring from
output terminals – if OL is still
indicated, problem may be due to
noise or faulty inverter cards

1753B

95547

30011

Inv Overloaded

OL2 – Drive overload. Protects the
Smart Trac AC1 drive. Drive
overload protection has tripped.

Yes

Yes

Yes

Minor

Major

See fault “Motor Overloaded” for
details.

1753C

95548

30012

Overtorque Det 1

OL3 – Overtorque detect 1. Output
current exceeded Overtorque
Detection Level 1 set in inverter
parameter L6-02.

Yes

Yes

Yes

Minor

Major

Declared only if inverter parameter
L6-01= 3 or 4. Reduce load, increase
acceleration time, or increase inverter
parameter setting L6-02.

1753D

95549

30013

Overtorque Det 2

OL4 – Overtorque detect 2. Output
current exceeded Overtorque
Detection Level 2 set in inverter
parameter L6-05.

Yes

Yes

Yes

Minor

Major

Declared only if inverter parameter
L6-04= 3 or 4. Reduce load, increase
acceleration time, or increase inverter
parameter setting L6-05.

1753E

95550

30014

DynBrk Transistr

RR – Dynamic braking transistor
failure.

Yes

Yes

Yes

Minor

Major

Replace dynamic braking unit.