Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

12

Displayed Fault No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

Fault Legend

Description

15

21

Operand2
Invalid

2

nd

operand code within program

is unrecognized. Valid Opcodes
are add, subtract, AND, OR, etc.

Yes

Yes

Yes

Major

Major

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. Replace the SmartTrac
CPU card.

16

22

Operand1
Invalid

1

st

operand code within program

is unrecognized. Valid Opcodes
are add, subtract, AND, OR, etc.

Yes

Yes

Yes

Major

Major

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.

17

23

Invalid Jump

Calculated offset appears outside
the bounds of the program.
Branch cannot be completed.

Yes

Yes

Yes

Major

Major

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.

18

24

Invalid
Address

Address does not appear within
NVRAM, DRAM, nor Task
table.

Yes

Yes

Yes

Major

Major

Check memory allocation for this node in Smart
Trac Workstation software. In Configure dialog
box, make sure the following is true: Base
Address = 0x300000, Base Memory Size =
0x100000, Retentive Address = 0xDC000, and
Retentive Size = 0x3F00. The Smart Trac main
CPU card may be faulty. If available, download
a small test program to see if fault persists