Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 40

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 39 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

39

Displayed Fault

No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

In

ternal Fault

No
.

Fault Legend

Description

17533

95539

30003

MC Answerback

UV3 – Main contactor fault. Main
circuit magnetic contactor (soft
charge contactor) does not operate
correctly.

Yes

Yes

Yes

Minor

Major

Check contactor wiring. Inspect
contactor for damage and defects.
Note: fault is declared only if drive is
in Run mode.

17534

95540

30004

Short Circuit

SC – Short circuit on Smart Trac
AC1 inverter PCB output terminals
(motor wiring).

Yes

Yes

Yes

Minor

Major

Check for correct motor
wiring/capacity. Note: fault is
declared only if drive is in Run
mode.

17535

95541

30005

Ground Fault

GF – Ground fault. Drive output
ground current exceeded 50% of
drive rated current.

Yes

Yes

Yes

Minor

Major

Check for correct motor
wiring/capacity. Look for shorts
between motor leads and ground.
Inverter power transistor(s) may be
damaged. Note: fault is declared only
if drive is in Run mode.

17536

95542

30006

Overcurrent

OC – Overcurrent. Output current
exceeded 200% of drive rated
current.

Yes

Yes

Yes

Minor

Major

Acceleration time may be set too
low. Motor load may be too great for
drive to handle. Motor may be
jammed or defective. Note: fault is
declared only if drive is in Run
mode.

Advertising