Smart trac, Faults.doc – Yaskawa SmartTrac Fault Tables User Manual

Page 17

Advertising
background image

10/17/00

New Berlin

Technology Center

Smart Trac

Product

Development

Design

Document

Faults.doc

Rev. # 19

Page 16 of 64

Title: Fault Declarations

The information contained in this document is the

CONFIDENTIAL

property of

MagneTek Inc.

File = N:\PROJECT\515\SmartTrac\DOCS\Faults.DOC

Print Date: 10/17/00

16

Displayed Fault No.

Priority

D

is

p

lay?

Newest

List

?

Ol
d

es

t

List

?

Severity

Assig

n

Program

Input

Corrective Action

Control

Node

Monitor

Fault

Manager

Fault Legend

Description

27

39

Bad Bit
Number

Requested bit number is
unavailable.

No

Yes

Yes

Minor

Minor

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.

28

40

Bad Data Size

Mismatch found when
performing computation on 2
differing data types.

No

Yes

Yes

Minor

Minor

Check application program for data type
mismatches.

29

41

Bit Out of
Range

Logical bit does not fit within
bounds of data type. For
example, an attempted was made
to OR bit 0x0800 with a byte.

No

Yes

Yes

Minor

Minor

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.

2A

42

Bad Function
Ptr

Pointer to a Function Block call
is invalid. ‘C’ FB cannot be
processed.

No

Yes

Yes

Minor

Minor

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.

2B

43

Bad Lower
Bound

Index into an internal array has
exceeded the lower bounds.

No

Yes

Yes

Minor

Minor

Verify that there are no hardware problems on
the PC used to create the application. Re-
compile and reload the program and reload it to
the SmartTrac drive. The Smart Trac main CPU
card may be faulty. If available, download a
small test program to see if fault persists.