4 port troubleshooting, Roubleshooting – PLANET WGSW-50040 User Manual

Page 70

Advertising
background image

6-3

Figure 6-1 Port Configuration Example

No VLAN has been configured in the switches, default VLAN1 is used.

Switch

Port

Property

Switch1

1/7

Ingress bandwidth limit: 150 M

Switch2

1/8

Mirror source port

1/9

100Mbps full, mirror source port

1/10

1000Mbps full, mirror destination port

Switch3

1/12

100Mbps full

The configurations are listed below:

Switch1:

Switch1(config)#interface ethernet 1/7

Switch1(Config-If-Ethernet1/7)#bandwidth control 50 both

Switch2:

Switch2(config)#interface ethernet 1/9

Switch2(Config-If-Ethernet1/9)#speed-duplex force100-full

Switch2(Config-If-Ethernet1/9)#exit

Switch2(config)#interface ethernet 1/10

Switch2(Config-If-Ethernet1/10)# speed-duplex force1000-full

Switch2(Config-If-Ethernet1/10)#exit

Switch2(config)#monitor session 1 source interface ethernet1/8;1/9

Switch2(config)#monitor session 1 destination interface ethernet 1/10

Switch3:

Switch3(config)#interface ethernet 1/12

Switch3(Config-If-Ethernet1/12)#speed-duplex force1000-full

Switch3(Config-If-Ethernet1/12)#exit

6.4 Port Troubleshooting

Here are some situations that frequently occurs in port configuration and the advised solutions:

 Two connected fiber interfaces won’t link up if one interface is set to auto-negotiation but the other to

forced speed/duplex. This is determined by IEEE 802.3.

 The following combinations are not recommended: enabling traffic control as well as setting multicast

limiting for the same port; setting broadcast, multicast and unknown destination unicast control as well

as port bandwidth limiting for the same port. If such combinations are set, the port throughput may fall

below the expected performance.