TYPE 2: Time-tagged with relative time

Bytes

Description

Spec

1

Value of 2

1

0x81

1

COT

1

Common address of ASDU

1

Function Type

1

Information number

1

DPI (0 to 3)

7.2.6.5

2

RET (relative time)

7.2.6.15

2

FAN (fault number)

7.2.6.6

4

4-octet binary time

7.2.6.28

1

SIN

7.2.6.23

TYPE 3: Measurands l

Bytes

Description

Spec

1

Value of 3

1

i = value of 1, 2 or 4

1

COT

1

Common address of ASDU

1

Function Type

1

Information number

2

Current L

2

7.2.6.8

2

Voltage L

1

-L

2

7.2.6.8

2

Active power P

7.2.6.8

2

Reactive power Q

7.2.6.8

ASD U3.1: i=1

ASDU 3.2: i=2

ASDU 3.3: i=4

ASDU 3.4: i=2 val1=I

N

and val2=V

EN