Panasonic TH-55VF2HW 54.6" Full HD Video Wall Display User Manual

Page 55

Advertising
background image

55

English

[Serial response (Normal)]

Sets whether to send the response command to normal

commands without ID.

[Off]:

Does not respond. (Including the inquiry command)

[On]:

Responds.

[Serial response(ID all)]

Set whether to respond to the command or not, when

serial command of ID number “0” is received.

[Off]:

Does not respond.

[On]:

Responds.

[Serial ID group]

When controlling multiple displays simultaneously via

serial communication, those displays are grouped as

one.

A to G

(7 groups)

[Serial response(ID group)]

Sets whether to respond to the command or not,

when serial command, which the group is specified, is

received.

[Off]:

Does not respond.

[On]:

Responds.

[Serial daisy chain position]

Sets the first and the last terminals of the daisy chain

connection when serial-controlling this unit by the

daisy chain connection (including connection via the

SERIAL IN/OUT terminal or via DIGITAL LINK, or mixed

connection).

[---]:

When controlling this unit alone with serial control, or

connecting at a position other than the first and last

terminals in a daisy chain

[Top]:

When connecting at the first terminal in a daisy chain

[End]:

When connecting at the last terminal in a daisy chain

[Multi control auto setting(DIGITAL LINK)]

When connected with the DIGITAL LINK daisy chain,

display IDs are automatically assigned to all the

displays, and the serial IN/OUT terminals, remote control

IN/OUT terminals and the network are automatically set.

Select [Multi control auto setting(DIGITAL LINK)]

with and press <ENTER>.

1

0

192.168.0.8

Multi control auto setting(DIGITAL LINK)

Status

Display ID

Start

Network control / IP address

Display ID

Wait

Yes

Off

Changing network control

DIGITAL LINK daisy chain

020/025

Serial ID / Terminal

On

SERIAL IN

Serial out terminal

SERIAL OUT

Controller ID / Terminal

On

Built-in

Controller out terminal

IR OUT

Yes

Changing Serial/IR terminal

The following screen is displayed on the subsequent-

stage displays.

0

192.168.0.8

Multi control auto setting(DIGITAL LINK)

Status

Display ID
Network control / IP address

Wait

Off

DIGITAL LINK daisy chain

021/025

[Status]

Displays the execution state of the display ID auto

setting.

[Wait]:

ID auto setting has not been executed yet.

[Finished]:

ID auto setting is completed.

[DIGITAL LINK daisy chain]

Displays the connection number counted from the

first unit to this unit out of total displays connected via

DIGITAL LINK.

[Display ID]

Displays the current display ID.

[Network control / IP address]

Displays [On] / [Off] of [Network control] function and

IP address.

[Serial ID / Terminal]

Displays ON/OFF of the function to control with

ID, and displays the terminal to use when serial-

controlling.

[Serial out terminal]

Displays the terminal used for the serial

communication output.

[Controller ID / Terminal]

Displays ON/OFF of the function to control with ID,

and displays the terminal to use when controlling with

the remote control.

Advertising