Chapter 4 Provisioning the TimeProvider
Provisioning the IOC

106 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

Sample Command

SET-SYS-MODE:::TS1000::SYSMODE=SUB;

Sets the system mode to Subtending (SUB). The inputs are set as described in the
table above. Record the mode in

Table 4-4

.

Autonomous Message

TP-SSU 03-10-24 10:40:10

A 1176 REPT EVT

“SYS,EQPT:NA,SYSMODE,NSA,03-10-24 10-40-10:\"SYSTEM MODE

OF OPERATION HAS CHANGED,SUB\””

;

Retrieving the Current System Mode
Use the RTRV-SYS-MODE command to retrieve the current system mode: SSU,
SUB, or PRR.

RTRV-SYS-MODE:[<tid>]::[<ctag>];

This command has a default access level of USER.

Sample Command

RTRV-SYS-MODE:::TS1000;

Normal Response

TP-SSU 03-10-24 10:37:54

M

TS1000 COMPLD

SSU

;

SYSMODE
(cont’d)

SUB

Set the TimeProvider to Subtending operating mode

PRS – Monitor only and Disabled, cannot be
Enabled

INP1 – Priority 1 and Enabled

INP2 – Priority 2 and Enabled

GPS – Monitor only and Disabled, cannot be
Enabled

SSU

PRR

Set the TimeProvider to Primary Reference
Receiver mode

PRS – Enabled as Backup Reference, can be
set to Monitor or Disabled

INP1 – Enabled as Backup Reference, can be
set to Monitor or Disabled

INP2 – Enabled as Backup Reference, can be
set to Monitor or Disabled

GPS – Enabled and Priority 1

<keyword>