Symmetricom EDGE CLOCK 1000 User Manual

Page 183

Advertising
background image

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 183

Chapter 6 Maintaining and Troubleshooting the TimeProvider

Troubleshooting the TimeProvider

INPQL

The received SSM on the
specified input is of lesser
quality than the local oscillator’s
QLEVEL.

T1

NSA

MN

MN

MN

INPTRR

Specified input port has a
Tip/Ring reversal on its
connection to the system.

T1

NSA

MN

MN

MN

EXDSC

Specified input port has exces-
sive discontinuities, indicated by
more than 3 signal faults of the
same time within 5 minutes.
Alarm clears when there are less
than 3 faults in a 5 minute
period.

T1

NSA

MN

MN

MN

MTIE

The specified input port has
exceeded at least 1 of the MTIE
alarm thresholds.

T1

NSA

MN

MN

MN

AID = E422A, E422B, E422C, E422D

E422
FAULT

The EIA-422 Output is not
functioning properly.

T1

NSA

NA

NA

NA

AID = RTMA[-p], RTMB[-p], RTMC[-p], RTMD[-p]

S1LOS

LOS on Side 1

T1

NSA

MN

MN

Mn

S2LOS

LOS on Side 2

T1

NSA

NA

NA

NA

EXSLIP

Excessive Slip Rate

T1

NSA

NA

NA

NA

RTM
FAULT

The Retimer module is not
functioning properly.

T1

NSA

NA

NA

NA

Table 6-7. Alarm Codes (Continued)

Event ID

Description

AID

TYPE

Service

Affecting

Alarm Level

SSU

Mode

PRR

Mode

SUB

Mode