Symmetricom EDGE CLOCK 1000 User Manual

Page 180

Advertising
background image

Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider

180 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

INP
PHASE

The specified input port has an
excessive phase measurement
that disqualifies it from being
used.

T1

NSA

MN

MN

MN

EXDSC

The input has had excessive
discontinuities, indicated by
more than 3 signal faults of the
same type within a 5-minute
window. The alarm clears when
the window contains less than 3
alarms of the same type.

T1

NSA

MN

MN

MN

FFOFF

The specified input port has
exceeded the Fractional
Frequency Offset threshold.

T1

NSA

MN

MN

MN

MTIE

The specified input port has
exceeded at least 1 of the MTIE
alarm thresholds.

T1

NSA

MN

MN

MN

TPIUSIG

The interface to the TPIU has a
connectivity issue.

T1

NSA

MN

MN

MN

AID = PRS

INPDISQ

The specified input port has
been disqualified or qualified as
a possible system reference.
The fault condition must be
continuously present for the
FLTDELAY period before
disqualifying the input as a
possible reference. Once set,
this alarm clears when the input
is fault-free for the CLRDELAY
period.

T1

NSA

MN

MN

MN

INPLOS

The specified input port has a
LOS. When detected, the input is
immediately removed as a possi-
ble reference. The LOS must be
continuously present for the FLT-
DELAY period before disqualify-
ing the input as a possible
reference. The alarm clears
when the input signal is fault-free
for the CLRDELAY period.

T1

NSA

MN

MN

MN

Table 6-7. Alarm Codes (Continued)

Event ID

Description

AID

TYPE

Service

Affecting

Alarm Level

SSU

Mode

PRR

Mode

SUB

Mode

Advertising