Chapter 7 Specifications of the TimeProvider
Alarms

200 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

Alarms

Input Alarms

The PRS input is inhibited when a contact closure (less than 1

Ω) is present across

the PRS Alarm In connection.

Output Alarms

The output alarm connector is on the Input module, and can be either a DB25
connector or wire-wrap pins. See

Making Alarm Connections

, on page 70

,

for a

pinout diagram of the DB-25 connector.

Table 7-6

describes the contact closure for

the alarm outputs.

Power

Dual power supplies from –36 to –72 V DC.

Table 7-7

lists the maximum and typical

power consumption using crystal and Rubidium IOCs.

Symmetricom recommends a 5 A fuse for the power supply to the TimeProvider
shelf.

Table 7-6. Output Alarm Specifications

Alarm

Description

Minor

Contact closure (NC or NO) 1 Amp Form C

Major

Contact closure (NC or NO) 1 Amp Form C

Critical

Contact closure (NC or NO) 1 Amp Form C

Table 7-7. Typical Power Consumption

IOC Type

Max Power (W)

per IOC

Typical Power (W)

per IOC

Crystal

40

30

Rubidium

60

40

(70 with two Rb IOCs)