Chapter 4 Provisioning the TimeProvider
Setting Communications Parameters

92

TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

Setting the Handshaking (Flow) Mode
Use the ED-EQPT command to provision the handshaking mode on the local Craft
or Remote port to None, Hardware, Software, or Hardware/Software.

ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;

This command has a default access level of ADMIN.

Sample Command

ED-EQPT::COML:TS1000::FLOW=HW;

Normal Response

TIMEPROVIDER 03-10-24 10:12:33

M

TS1000 COMPLD

;

Setting the Echo Mode
Use the ED-EQPT command to provision the echo mode on the local Craft or
Remote port to On or Off. When set to ENABLE, characters you type at the
keyboard also appear on the monitor. If one keystroke generates two characters on
the monitor, set this parameter to DISABLE.

You can also use ED-EQPT to echo the <tid> in the response from the TimeProvider.

ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>[=<value>];

This command has a default access level of ADMIN.

Sample Command

ED-EQPT::COML:TS1000::ECHO=ENABLE;

Normal Response

TIMEPROVIDER 03-10-24 10:15:04

M

TS1000 COMPLD

;

<aid>

<keyword>

<value>

Description

Default value

COMp
p = L | R

FLOW

NONE | SW |
HW | SWHW

Flow control

NONE

<aid>

<keyword>

<value>

Description

Default value

COMp
p = L | R

ECHO

ENABLE | DISABLE

Input echo

DISABLE

TIDQUIET

ENABLE | DISABLE

Enables or disables the
echo of the <tid>. This
is a session setting.

DISABLE