Chapter 3 Installing the TimeProvider
Installing Connections to the Ethernet Port

80

TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

Changing Communications Settings

To change the communication settings for the local or remote serial ports:

1. Connect a PC or laptop with terminal emulation software, such as Windows

®

Hilgraeve HyperTerminal

©

or ProComm Plus

to the port and log in. For a

complete description of this procedure, see

Setting Communications

Parameters

, on page 91

.

2. Use the ED-EQPT command to change the communications settings for the port

as required. See

Setting Communications Parameters

, on page 91, and also

refer to the TimeProvider TL1 Reference Guide for a description of TL1
commands.

Installing Connections to the Ethernet Port

You can connect a PC or terminal to the TimeProvider using the LAN connector for
local monitoring or control, or you can connect the TimeProvider to a network for
monitoring and control from a remote site.

Direct Ethernet Connection
You use a direct Ethernet connection when a service technician is on-site. You must
configure the Ethernet settings using TL1 commands over a serial connection
before you can use the Ethernet connection. Use the direct connection to
troubleshoot a LAN connection.

To connect the TimeProvider to a PC or terminal, perform the following steps:

1. Connect an RJ-45 Ethernet crossover cable to the LAN connector on the shelf.

2. Connect the other end of the cable to the PC or terminal.

3. Start a terminal emulation program such as HyperTerminal or ProComm Plus.

Configure the program for a telnet session and enter the IP address of the
TimeProvider. Use Port 5000 to connect.

4. Type

;

(semicolon). If the TimeProvider responds with a Deny response, you

have established communications. If you do not receive the Deny response,
check the connections, the cable, and the program settings.

Note: The TimeProvider can be controlled through a TCP/IP
network connection, but before you can use it, you must
configure the Ethernet settings using a serial connection. Refer to

Setting Ethernet Parameters

, on page 93.