097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 115

Chapter 4 Provisioning the TimeProvider

Provisioning the Input Reference

Provisioning the SSM

Before you can read Synchronization Status Messages (SSMs) on certain input
signals, you need to provision the TimeProvider to read the incoming SSM and
identify the bit position of the SSM. SSMs are on the following types of input signals:

E1, CAS4, CCS4

T1, ESF

Reading SSMs
To enable the use of SSMs, you must first provision the TimeProvider to read SSMs
on the input. Use the ED-SYNC command to enable the specified input to read SSMs.

ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;

This command has a default access level of ADMIN.

Sample Command

ED-SYNC::INP1:TS1000::SSMENA=ENABLE;

Autonomous Message

TP-SSU 03-10-24 11:02:28

A 1186 REPT EVT

“INP1,T1:NA,SSMENA,NSA,03-10-24 11-02-28:\"INPUT READING

OF SSM HAS CHANGED,ENABLE\””

;

Defining the SSM Bit Position
After you enable an E1 (CAS/CAS) input to read SSMs, you must then define the bit
containing the SSM.

ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;

This command has a default access level of ADMIN.

Sample Command

ED-SYNC::INP1:TS1000::SSMBIT=4;

<aid>

<keyword>

<value>

Description

Default value

INPp
p = 1 | 2

SSMENA

ENABLE |
DISABLE

Provisions the T1 ESF or
E1 (CAS/CCS) input to
read the received SSM

ENABLE

<aid>

<keyword>

<value>

Description

Default value

INPp
p = 1 | 2

SSMBIT

4 | 5 | 6 | 7 | 8

Provisions the E1 (CAS/
CCS) SSM bit position.

8