Checking communication links, Defining the security parameters, Dure in – Symmetricom EDGE CLOCK 1000 User Manual

Page 94

Advertising
background image

Chapter 4 Provisioning the TimeProvider
Defining the Security Parameters

94

TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

Checking Communication Links

Two commands allow you to check the communication links from a computer or
network to the TimeProvider: PING and RTRV-HDR.

Ping
Use the PING command to check an Ethernet connection to the TimeProvider.

PING:[<tid>]::[<ctag>]::<ipaddr>;

This command has a default access level of USER.

Sample Command

PING:::TS1000::192.168.12.10;

Normal Response

TP-SSU 03-05-15 09:59:09

M

TS1000 COMPLD

“Host 192.168.12.10 is alive. Roundtrip time was 165 ms”

;

Retrieve Header
Use the RTRV-HDR command to display the response header, which includes the
system identification <sid>, date, and time. You can also use this command to verify
that the communication link to the TimeProvider is working properly.

This command has a default access level of NONE.

Sample Command

RTRV-HDR:::TS1000;

Normal Response

TP-SSU 03-05-15 09:59:25

M

TS1000 COMPLD

;

Defining the Security Parameters

The TimeProvider supports users at the following four access levels:

None – Anyone with access to a serial or Ethernet port on the TimeProvider can
issue commands set to this access level. If no Security-level users are defined,
then anyone connected to the TimeProvider can issue every command available

<ipaddr>

Value

Description

IP address of host to be pinged

1.0.0.1 – 254.254.254.254

Pings the host system

Advertising
This manual is related to the following products: