Retrieving current alarm settings – Symmetricom EDGE CLOCK 1000 User Manual

Page 131

Advertising
background image

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 131

Chapter 4 Provisioning the TimeProvider

Provisioning Alarms

Sample Command

ED-SYNC::SYS:TS1000::CLRDELAY=5;

This command declares a faulted input to be valid five seconds after the alarm
condition has cleared.

Autonomous Message

TP-SSU 03-10-24 11:18:00

A 1192 REPT EVT

“SYS,EQPT:NA,CLRDELAY,NSA,03-10-24 11-18-00:\"INPUT CLEAR

DELAY HAS CHANGED\””

;

Retrieving Current Alarm Settings

You can display the current settings for any alarm using the RTRV-ATTR command.

RTRV-ATTR:[<tid>]:<aid>:[<ctag>][::<keyword>];

This command always has an access level of USER.

SYS
(cont’d)

GPSCLRDEL

0 to 1000 s

Sets the time delay to
declare GPS is valid after
an alarm condition clears

5

GPSFLTDEL

1 to 1000 s

Sets the time delay before a
GPS fault is declared

1

<aid>

<keyword>

Description

SYS

ELEVTIME

ENABLE | DISABLE

SYS
IMC
IOC
PRS
INPp (p = 1 | 2)

Alarm ID

The Alarm ID is described in

Provisioning

the Alarm Levels

, on page 126

ALL (or null)

ALL (or null)

Returns all of the alarm attributes

<aid>

<keyword>

<value>

Description

Default value

Advertising