Setting the input priority level – Symmetricom EDGE CLOCK 1000 User Manual

Page 113

Advertising
background image

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 113

Chapter 4 Provisioning the TimeProvider

Provisioning the Input Reference

ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;

This command has a default access level of ADMIN.

Sample Commands

ED-SYNC::PRS:::QLEVEL=1;

ED-SYNC::INP1:::QLEVEL=1;

ED-SYNC::INP2:::QLEVEL=1;

This series of commands sets the QLEVEL for all inputs to the same level; if you
also provision the PRIORITY level to the same value, then you have set up a
non-revertive switching strategy.

Autonomous Message

TP-SSU 03-10-24 10:54:44

A 1183 REPT EVT

“PRS,EQPT:NA,QLEVEL,NSA,003-10-24 10-54-44:\"USER

ASSIGNED QUALITY LEVEL HAS CHANGED,1\””

;

Setting the Input Priority Level

The PRIORITY level works together with the QLEVEL parameter (described in

Setting the Input Quality Level

, on page 112) to determine the switching strategy.

The PRIORITY level is the second factor the TimeProvider uses to determine which
input to use when the original primary input becomes unavailable.

Use the ED-SYNC command to set the PRIORITY level of the selected reference.

ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;

This command has a default access level of ADMIN.

<aid>

<keyword>

<value>

Description

Default value

PRS
INPp (p = 1 | 2)
GPS

QLEVEL

1 = PRC
2 = UNK/STU
3 = TYPE II/ST2
4 = TYPE I
5 = TYPE V/TNC
6 = TYPE III/ST3E
7 = TYPE IV/ST3
8 = G.813OPT3/SMC
9 = DUS

Sets the Quality
Level for the
specified input

2

<aid>

<keyword>

<value>

Description

Default value

PRS
INPp (p = 1 | 2)
GPS

PRIORITY

2 | 3 | 4

Sets the priority for
the selected input

GPS = 1
PRS = 2
INP1 = 3
INP4 = 4