Ssu-based reference selection scenarios, Subtending-based reference selection scenarios, Table 1-2 – Symmetricom EDGE CLOCK 1000 User Manual

Page 37: Illustrates which in

Advertising
background image

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide

37

Chapter 1 Overview of the TimeProvider

Reference Input Signals

Subtending Mode

Table 1-3

illustrates which input is the active system reference under several

different input conditions when the TimeProvider is in the Subtending mode.

Table 1-2. SSU-Based Reference Selection Scenarios

Sequence

QLevel on

PRS

QLevel on

INP1

QLevel on

INP2

Active Reference

Non-Revertive

1

Note:

1

Non-revertive example. Priority Levels set to: PRS = 3, INP1 = 3, and INP2 = 3

Revertive

2

2

Revertive example. Priority Levels set to: PRS = 2, INP1 = 1, and INP2 = 2

1

2

2

2

PRS

INP1

2

4

2

2

INP1

INP1

3

4

4

2

INP2

INP2

4

4

4

4

INP2

INP1

5

4

4

2

INP2

INP2

6

4

2

2

INP2

INP1

7

2

2

2

INP2

INP1

8

2

2

LOS

PRS

INP1

9

2

LOS

2

PRS

PRS

10

LOS

LOS

2

INP2

INP2

11

LOS

LOS

LOS

Holdover

Holdover

12

LOS

LOS

2

INP2

INP2

13

2

LOS

2

INP2

PRS

14

2

2

2

INP2

INP1

Table 1-3. Subtending-Based Reference Selection Scenarios

Sequence

QLevel on

INP1

QLevel on

INP2

Active Reference

Non-Revertive

1

Revertive

2

1

1

1

INP1

INP1

2

2

1

INP2

INP2

3

2

2

INP2

INP1

4

2

1

INP2

INP2

5

1

1

INP2

INP1

6

1

LOS

INP1

INP1