Symmetricom EDGE CLOCK 1000 User Manual

Page 172

Advertising
background image

Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider

172 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

FRMTYPE

Indicates the type of
input framing or the
input frequency. Sets
the input framing type

T1

Output = 2M

1.544M – 1.544 MHz
2M – 2048 kHz
6.312M – 6.312 MHz
CAS – CAS Input
CCS – CCS Input
ESF – Extended SuperFrame
input
CC – Composite Clock input
ISOLATED_1 – Generates an
isolated one test pattern for
T1 outputs
JCC – Japan Composite Clock
JCC4 – Japan Composite
Clock with 400 Hz

OUTSTATE

The specified output
state has changed

T1

DISABLE

ENABLE – The output
generates the defined signal
type
DISABLE – Disables the
output and clears all active
alarms associated with the
input

RQLEVEL

The received quality
level on the specified
input has changed

T1

n/a

Displays the prior quality level
followed by the new quality
level

SYS Events

CLRDELAY

Time, in seconds,
before a faulted signal
indicates it is valid as a
system reference

EQPT

5 s

0 to 1000 s

ELEVTIME

Indicates that Alarm
elevation time (1440
min.) is enabled or
disabled

EQPT

DISABLE

ENABLE | DISABLE

FACTORY

Indicates that the unit
has been reset to
Factory default. All
modules installed in
the system are reset

EQPT

n/a

n/a

FLTDELAY

Time, in seconds,
before faulted signal
indicates it is not valid
as a system reference

EQPT

10 s

1 to 15 s

Table 6-5. Event Codes (Continued)