Chapter 4 Provisioning the TimeProvider
Provisioning Alarms

128 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

CLKWARM

Local oscillator on the
specified IOC is in
Warm-up mode

MN | MJ

IMMED

No

MN

MN

CLKFREE

Local oscillator on
specified IOC is in
Free-run mode

MN | MJ |
CR

IMMED

No

MJ

MJ

CLKBRDG

Local oscillator on
specified IOC is in
Bridging mode

MN | MJ |
CR

IMMED

No

MJ

MJ

CLKHOLD

Local oscillator on
specified IOC is in
Holdover mode

MN | MJ |
CR

IMMED

No

MJ

MJ

<aid> = PRS

INPDISQ

Specified input has
been disqualified or
qualified as a possible
system reference.

MN | MJ |
CR

FLT
DELAY

Yes

MN

MN

INPLOS

Specified input has

Loss Of Signal.

1

MN | MJ |
CR

IMMED

No

MN

MN

INPFRQ

Specified input has
calculated received
frequency that exceeds
the pull-in range of the
LO.This alarm condition
disqualifies the input as

a possible reference.

2

NR | NA |
MN | MJ |
CR

IMMED

No

MN

NR

INPPHASE

Specified input port’s
phase measurement
exceeds usable value.

NR | NA |
MN | MJ |
CR

IMMED

No

MN

MN

EXDSC

Input has had excessive
discontinuities, indicated
by more than 3 signal
faults (OOF, BPV, CRC,
or AIS) within a 5-minute
window. The alarm
clears when the
5-minute window
contains less than 3
signal faults.

NR | NA |
MN | MJ |
CR

IMMED

No

MN

MN

Table 4-3. Alarm Conditions and Defaults (Continued)

Alarm ID

Description of Alarm

Condition

Possible

Alarm

Levels

Error

Delay

Default

Error

Delay

Editable?

Default Level

SSU

Mode

SUB

Mode