Clearing alarms – Symmetricom EDGE CLOCK 1000 User Manual

Page 135

Advertising
background image

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 135

Chapter 4 Provisioning the TimeProvider

Provisioning Alarms

Sample Command

RTRV-COND::IOC:TS1000;

Normal Response

TP-SSU 03-10-24 11:27:28

M

TS1000 COMPLD

“SYS,PWRA-OK,PWRB-OK,OK,OK”

;

Clearing Alarms

Clearing the Office (Audible) Alarm
Use the following TL1 command to turn off (squelch) the audible office alarm. The
office alarm reactivates when a new alarm occurs.

OPR-ACO-ALL:[<tid>]::[<ctag>];

<aid>

Description

SYS

Displays the connectivity status of the Expansion Panel and any
alarms associated with the Expansion Panel
<pwra> – PWRA-OK | PWRA-FAIL
<pwrb> – PWRB-OK | PWRB-FAIL
<expstatus> – OK | ALM
<extfault> – OK | ALM

IMC

Displays all conditions related to the Information Management module
<ioc1comm> – IOC1COMM-OK | IOC1COMM-FAIL
<ioc2comm> – IOC2COMM-OK | IOC2COMM-FAIL

IOCm
m = 1 | 2

Displays the current setup and conditions related to the system-level
function of the IOC module
<iocstatus> – OK | ALM (IOCFAIL)
<ioccomm> – IOC1TO2COMM-OK | IOC1TO2COMM-FAIL
IOC2TO1COMM-OK | IOC2TO1COMM-FAIL
<imccomm> – IMC1COMM-OK | IMC1COMM-FAIL |
IMC2COMM-OK | IMC2COMM-FAIL

GPS

Displays GPS Input state and any alarm events associated with GPS
input
<gpsstatus> – OK | ALM

PRS

Displays PRS Input state and any alarm events associated with PRS
input
<prsstatus> – OK | ALM

INPp
p = 1 | 2

Displays Input state and any alarm events associated with Inputs 1 or 2
<inpstatus> – OK | ALM

OUTg
g = 1 | 2 | 3 | 4

Displays output status; this reflects the state of IOCFAIL of the active
IOC
<outstatus> – OK | ALM

Advertising