Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider

176 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

Using Alarm Codes to Troubleshoot

Table 6-7

lists the alarm codes generated by the TimeProvider. Unless specified,

each alarm has a default Error Delay of Immediate, and you cannot edit the Error
Delay.

INPTRR

Tip/ring reversal on CC input

Tip/ring connection correct on CC input

EXDSC

Excessive discontinuity fault

Excessive discontinuity cleared

MTIE

MTIE exceeded threshold

MTIE within threshold

OUT[g] Codes

OUTFAIL

Output fault

Output fault cleared

SYNTHEOR

Output generator exceeds pull-in range

Output generator within pull-in range

SYNTHFAIL

Output generator failed

Output generator restored

E422[g] Codes

E422EQPT

EIA-422 Output module is unequipped

EIA-422 Output module is equipped

E422FAULT

EIA-422 Output module has a fault

EIA-422 Output module fault cleared

RTMg[-p] Codes

RTMEQPT

Retimer module is unequipped

Retimer module is equipped

S1LOS

Side 1 LOS fault

Side 1 LOS fault cleared

S2LOS

Side 2 LOS fault

Side 2 LOS fault cleared

EXSLIP

Slip rate threshold exceeded

Slip rate within threshold

RTMFAULT

Retimer module has a fault

Retimer module fault cleared

Table 6-7. Alarm Codes

Event ID

Description

AID

TYPE

Service

Affecting

Alarm Level

SSU

Mode

PRR

Mode

SUB

Mode

AID = SYS

COMPAT

System components (hardware
or software) are incompatible.

EQPT

NSA

MJ

MJ

MJ

Table 6-6. Set and Clear Conditions for Alarms (Continued)

Alarm ID

Set Alarm Conditional Description

Clear Alarm Conditional Description