Chapter 4 Provisioning the TimeProvider
Provisioning the Input Reference

116 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

This command sets the SSM bit to position 4 in the E1 input string on Input 1.

Autonomous Message

TP-SSU 03-10-24 11:05:18

A 1187 REPT EVT

“INP1,T1:NA,SSMBIT,NSA,03-10-24 11-05-18:\"E1 SSM BIT HAS

CHANGED,4\””

;

Enabling CRC4

Use the ED-SYNC command to enable or disable the use of CRC4 on E1 inputs.

ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;

This command has a default access level of ADMIN.

Sample Command

ED-SYNC::INP1:TS1000::CRCENA=ENABLE;

Normal Response

TP-SSU 03-10-24 11:06:57

A 1188 REPT EVT

“INP1,T1:NA,CRCENA,NSA,03-10-24 11-06-57:\"INPUT CRC HAS

CHANGED,ENABLE\””

;

Using Performance Monitoring

You can set thresholds for alarms and for qualifying inputs using MTIE and FFOFF
data. For more information on performance monitoring, see

Performance

Monitoring

, on page 24.

Setting MTIE and FFOFF Thresholds
Use the SET-TH command to set the alarm thresholds for each input and each
MTIE window.

SET-TH:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;

This command has a default access level of ADMIN.

<aid>

<keyword>

<value>

Description

Default value

INPp
p = 1 | 2

CRCENA

ENABLE |
DISABLE

Provisions the use of
CRC4 on E1 inputs

DISABLE