Retrieving current alarms – Symmetricom EDGE CLOCK 1000 User Manual

Page 132

Advertising
background image

Chapter 4 Provisioning the TimeProvider
Provisioning Alarms

132 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

Response Format

<cr><lf><lf>

sid date time<cr><lf>

M

ctag COMPLD<cr><lf>

“<aid>:event id,alarm level”<cr><lf>

“<aid>:event id,alarm level”<cr><lf>

.

.

“<aid>:event id,alarm level”<cr><lf>

;

Sample Command

RTRV-ATTR::SYS:TS1000;

This command causes the TimeProvider to return the alarm levels associated with
all system-level alarms.

Normal Response

TP-SSU 03-10-24 11:21:20

M

TS1000 COMPLD

"SYS:IOC1EQPT,NA"

"SYS:IOC2EQPT,NA"

"SYS:PWRA,MJ"

"SYS:PWRB,MJ"

"SYS:EXTALM1,MJ"

"SYS:EXTALM2,CR"

"SYS:EXPFAIL,MJ"

;

Retrieving Current Alarms

You can display the current active alarms using the RTRV-ALM command.

RTRV-ALM:[<tid>]:<aid>:[<ctag>];

Field

Description

<aid>

The aid specified in the command

event id

The identifier of the alarm whose level is displayed

alarm level

The value indicates the alarm level that is generated by an alarm
event:
NR = Not Reported
NA = A non-alarm event
MN = Minor alarm
MJ = Major alarm
CR = Critical alarm