Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider

170 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

XFEROK

Transfer of the IMC
Istate to the IOC,
transfer of the IOC
Istate to the IMC, or
transfer of the IOC
Istate to the redundant
IOC was successful

EQPT

n/a

n/a

IOC Event Codes

CLKTYPE

The specified IOC
clock has been set to
the specified value.
This value is used to
define the IOCs pull-in
range and SSM
generation in Holdover
mode

EQPT

TYPEI

ST3E | TYPE I
ST2 | TYPE II

INPREF

The specified input
has been set as the
system reference

EQPT

PRS

PRS | INP1 | INP2

IOCMODE

The specified IOC has
become Active

EQPT

ACTIVE

ACTIVE | STANDBY

IOCSTATE

The specified IOC has
been inserted into the
system. The IOC is
automatically placed
In-Service

EQPT

INSRV

INSRV – In service

The specified IOC has
been taken out of
service. The IOC can
no longer generate
alarms, be
provisioned, or accept
queries

OOSRV – Out of service

Communication
between the IMC and
IOC has failed

COMMFLT –
Communications fault

The specified IOC has
been removed from
the system

UNEQUIPPED

Table 6-5. Event Codes (Continued)

Event ID

Keyword

Description

AID

TYPE

Default Value/

Keyword

Description of Values