Provisioning the lbo – Symmetricom EDGE CLOCK 1000 User Manual

Page 121

Advertising
background image

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 121

Chapter 4 Provisioning the TimeProvider

Provisioning Retimer Parameters

Autonomous Message

TP-SSU 03-10-24 11-09-12

A 1189 REPT EVT

“OUTA,EQPT:NA,OUTSTATE,NSA,03-10-24 11-09-12:\"OUTPUT

GROUP STATE HAS CHANGED,DISABLE\””

;

Provisioning the LBO

Use the ED-SYNC command to set the line build-out (LBO) for each port (1 or 2) on
the Retimer module.

ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;

This command has a default access level of ADMIN.

Sample Command

ED-EQPT::RTMA-1:TS1000::RTMLBO=2;

This command sets the line build-out length for port 1 in Retimer group A to 266 to
399 ft (80 to 121 m).

Autonomous Message

TP-SSU 03-10-24 11-09-12

A 1189 REPT EVT

“RTMA,EQPT:NA,OUTSTATE,NSA,03-10-24 11-09-12:\"LBO HAS

CHANGED,2\””

;

<aid>

<keyword>

<value>

Description

Default value

RTMg[-p]
g = A | B | C | D
p= 1 | 2
Note: The RTM-
LBO parameter is
valid only for T1
signals; for the
E1 Retimer, the
IPNV (Invalid
Parameter)
DENY code is
returned.

RTMLBO

0

Sets the line build-out
length to 0 to 133 ft
(0 to 40 m)

0

1

Sets the line build-out
length to 133 to 266 ft
(40 to 81 m)

2

Sets the line build-out
length to 266 to 399 ft
(80 to 121 m)

3

Sets the line build-out
length to 399 to 533 ft
(121 to 162 m)

4

Sets the line build-out
length to 533 to 650 ft
(162 to 198 m)

Advertising