Provisioning the input reference, Setting the input state, Scribed in – Symmetricom EDGE CLOCK 1000 User Manual

Page 108

Advertising
background image

Chapter 4 Provisioning the TimeProvider
Provisioning the Input Reference

108 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

Provisioning the Input Reference

You need to know the following information about the input reference signal before
you can provision the Input Reference signals:

Input selection mode

Interface type

Frame type/frequency

Quality level

Priority level

SSMs and bit position

CRC

Setting the Input State

Use the ED-EQPT command to provision the inputs to the TimeProvider. You can
enable, disable, or place an input in Monitor mode (where the input is monitored, but
cannot be selected as the system reference).

ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;

This command has a default access level of ADMIN.

Sample Command

ED-EQPT::INP1:TS1000::INSTATE=MONITOR;

This command places Input 1 in the Monitor mode.

Autonomous Message

TP-SSU 03-10-24 10:44:21

A 1178 REPT EVT

“INP1,T1:NA,INSTATE,NSA,03-10-24 10-44-21:\"INPUT STATE

HAS CHANGED,MONITOR\””

;

<aid>

<keyword>

<value>

Description

Default value

PRS
INPp (p = 1 | 2)
GPS

INSTATE

ENABLE

Enables the specified input

ENABLE
GPS = DISABLE

MONITOR

Places the specified input in
Monitor Only mode

DISABLE

Disables the specified input

Advertising