Use the ED-EQPT command to enable or disable the output signal. This command
affects the specified group of eight output channels, or sixteen output channels if the
Expansion panel is also used; individual channels cannot be enabled or disabled.

ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;

This command has a default access level of ADMIN.

Sample Command

ED-EQPT::OUTA:TS1000::OUTSTATE=DISABLE;

This command disables output group A and turns off all 8 channels, or 16 channels
if the Expansion Panel is also used.

Autonomous Message

TP-SSU 03-10-24 11-09-12

A 1189 REPT EVT

“OUTA,EQPT:NA,OUTSTATE,NSA,03-10-24 11-09-12:\"OUTPUT

GROUP STATE HAS CHANGED,DISABLE\””

;

Provisioning the Output Framing Type

Use the ED-SYNC command to provision the output framing type.

CAS and CCS are available for E1 output framing. D4 and ESF are available for T1
output framing.

ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;

This command has a default access level of ADMIN.

<aid>

<keyword>

<value>

Description

Default value

OUTg
g = A | B | C | D

OUTSTATE

ENABLE

Enable the specified
output group

ENABLE

DISABLE

Disable the specified
output group

<aid>

<keyword>

<value>

Description

Default value

OUTg
g = A | B | C | D

FRMTYPE

8K | 1.544M | 2M |
6.312M | CAS | CCS |
D4 | ESF | CC | JCC |
JCC4 | ISOLATED_1 |

Provisions the output
framing

2M