Chapter 4 Provisioning the TimeProvider
Provisioning Retimer Parameters

120 TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

Sample Command

ED-SYNC::OUTA:TS1000::FRMTYPE=CAS;

This command provisions output group A to an E1, CAS framing format.

Autonomous Message

TP-SSU 03-10-24 11:11:18

A 1190 REPT EVT

“OUTA,EQPT:NA,FRMTYPE,NSA,03-10-24 11-11-18:\"OUTPUT

FRAMING TYPE HAS CHANGED,CAS\””

;

Provisioning Retimer Parameters

You use several TL1 commands to provision the E1 and T1 Retimers available for
the TimeProvider. The ED-EQPT command with the RTMSTATE keyword allows
you to enable and disable Retimer modules and individual ports; the SLIPCLR
keyword allows you to clear a Slip alarm. The ED-SYNC command with the
RTMLBO keyword allows you to set the line build-out length; the FREEFLT and
HOLDFLT keywords allow you to enable or disable the cut-through mode when the
clock enters Free-run or Holdover mode.

Enabling and Disabling the Retimers

Use the ED-EQPT command to enable or disable the specified Retimer group.
Individual channels cannot be enabled or disabled.

ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;

This command has a default access level of ADMIN.

Sample Command

ED-EQPT::RTMA:TS1000::RTMSTATE=DISABLE;

This command disables the Retimer in group A and turns off both ports.

<aid>

<keyword>

<value>

Description

Default value

RTMg
g = A | B | C | D

RTMSTATE

ENABLE

Enable the specified
Retimer group

ENABLE

DISABLE

Disable the specified
Retimer group