Interpreting error messages, Replacing the imc or imc/tpiu, Replacing – Symmetricom EDGE CLOCK 1000 User Manual

Page 163: The imc or imc/tpiu

Advertising
background image

097-58001-02 Revision G – April 2008

TimeProvider User’s Guide 163

Chapter 6 Maintaining and Troubleshooting the TimeProvider

Diagnosing the IMC

Interpreting Error Messages

Error messages appear on the console as they occur, and include the time and date
of occurrence. Refer to the event codes described in

Table 6-5

and to the alarm

codes described in

Table 6-7

.

Replacing the IMC or IMC/TPIU

You can remove the IMC or the IMC/TPIU from the shelf and replace it without
affecting outputs.

1. Save the contents of the IMC memory in an IOC by issuing the following

command:

CPY-MEM:::::IMC,IOC,IMC;

This command may take more than two seconds to execute; if it does, then the
In-Process response is issued. See the TimeProvider TL1 Reference Guide for
more information on the CPY-MEM command.

2. Attach a wrist grounding strap and connect it to the TimeProvider chassis.

3. Remove the IMC by loosening the captive screws and pulling the IMC from the

shelf using the U-shaped handles.

Major

Red
Off

Major system alarm
No alarm

Minor

Yellow
Off

Minor system alarm
No alarm

Alarm Cutoff (ACO)

Green
Off

On
Off

Antenna Power
(IMC/TPIU only)

Green
Red
Off

Internal TPIU is communicating with Antenna
Internal TPIU has lost communication with Antenna
GPS is disabled

Antenna Signal
(IMC/TPIU only)

Green
Red
Off

Antenna is communicating with the internal TPIU
Master shelf is powering up
Antenna has lost communication with the internal TPIU

Warning: To avoid possible electrostatic damage to the IMC,
place it in a static-free bag or on a static-free surface.

Table 6-3. LED Conditions for the IMC and IMC/TPIU (Continued)

LED Name

Condition

Description

Advertising
This manual is related to the following products: