Chapter 4 Provisioning the TimeProvider
Managing the User List

98

TimeProvider User’s Guide

097-58001-02 Revision G – April 2008

Sample Command

CANC-USER::TECHNICIAN:TS1000;

This command logs out the user named Technician.

Autonomous Message

TP-SSU 03-10-24 10:25:31

A 1171 REPT EVT

“IMC,EQPT:NA,LOGOUT,NSA,03-10-24 10-25-31:\”USER LOGGED

OUT,TECHNICIAN\””

;

Adding a User

You can store up to 20 users in the TimeProvider’s user list. Each user has a name
of up to 20 case-insensitive alphanumeric characters, a password of up to 20
case-sensitive characters, and one of the four defined access levels.

Use the following TL1 command to add a user to the user list. If more than 20 users
are defined in the user list, the DENY response is sent. Only a Security-level user
can add to the user list.

ENT-USER-SECU:[<tid>]:<uid>:[<ctag>]::<pid>,<uap>;

This command always has an access level of SECURITY.

Sample Command

ENT-USER-SECU::TECHNICIAN:TS1000::TECH01!,USER;

This command creates a user named TECHNICIAN with a password of TECH01! at
the User access level.

Autonomous Message

TP-SSU 03-10-24 10:28:24

A 1172 REPT EVT

“IMC:NA,USRADD,NSA,03-10-24 10-28-24:\”USER HAS BEEN

ADDED\””

;

Parameter

Value

Description

<uid>

<username>

Up to 20 case-insensitive alphanumeric characters

<pid>

<user password>

Up to 20 case-sensitive characters. You must include at
least two non-alphabetic and one special character (other
than a letter, number, comma, colon, or semicolon). For
case-sensitive passwords, enclose the <pid> in quotes.

<uap>

NONE | USER |
ADMIN | SECURITY

The access level for the user specified by the <uid>

Advertising