<esmode>

The errored seconds alarm setting. Type

enable

or

disable

.

<uas>

The unavailable seconds threshold. When the number of unavailable seconds in the current
15-minute data collection interval exceeds the specified threshold, the UAS alarm is
activated. Unavailable seconds are seconds during which the SDSL frame loop is not
synchronized. A typical unavailable seconds threshold value is 60.

<uasmode>

The unavailable seconds alarm setting. Type

enable

or

disable

.

Example

::alarm=> new enable 6 enable 17 enable 60 enable

Displaying SDSL Frame Alarm Profiles

From the

::alarm=>

prompt, type the show command in the following format then press

.

show [<index>]

Parameter

[<index>]

The SDSL frame alarm profile table index number of the profile you want to display.
Omitting this parameter displays the entire SDSL frame alarm profile table.

Examples

::alarm=> show 1

::alarm=> show

ENTER