Modifying frame relay link settings – ADC AVIDIA SWD4573I1 User Manual

Page 233

Advertising
background image

Chapter 9: Configuring Frame Relay Interworking

Avidia System Configuration and Management User Manual

207

[-enqinterval <int>]

The inquiry interval value. Inquiry interval is the number of poll intervals before a full
status inquiry message is sent. The valid range is 1 to 255, with 6 as the default.

[-errthreshold <val>]

The error threshold value. Error threshold is the number of consecutive poll intervals in
which the LMI status inquiry messages are not received that are required for the link to be
declared down. The valid range is 1 to 10, with 3 as the default.

[-monevents <val>]

The monitor events value. Monitor events is the number of poll intervals in which the LMI
status inquiry messages are not received that are required for the link to be declared down.
The valid range is 1 to 10, with 4 as the default.

Example

::link=> new 5.1 -lmitype LMI -pollinterval 15 -enqinterval 6

-errthreshold 3 -monevents 4

Modifying Frame Relay Link Settings

From the

::link=>

prompt, type the set command in the following format then press

.

set <slot.port> [-lmitype (LMI|ANNEXA|ANNEXD|NONE)]

[-pollinterval <int>] [-enqinterval <int>] [-errthreshold <val>]

[-monevents <val>]

Parameters

<slot.port>

The channel card slot and port (format slot.port).

ENTER

Advertising