Deleting idsl alarm profiles – ADC AVIDIA SWD4573I1 User Manual

Page 436

Advertising
background image

Configuring IDSL Alarm Profiles

410

Avidia System Configuration and Management User Manual

4

In the

Daily SES

box, type the desired severely errored second threshold in seconds, or type

0

to disable this trap. The range is 0 to 2047, with 25 as the default.

The Daily SES Threshold is the number of severely errored seconds that must be met or
exceeded on the IDSL line within a day for an alarm to display. A severely errored second
generates when the number of block errors (CRC violations) defined by the SES threshold
parameter (see

“Adding ADSL Line Profiles” on page 387

) are detected during a one

second interval.

5

Click

Add

to add the IDSL alarm profile.

Deleting IDSL Alarm Profiles

1

In the

IDSL Alarm Configuration Profile Table

window, locate the table row that contains the

IDSL alarm configuration profile you want to delete.

Click

and

if necessary to view the entire table.

displays the beginning of the

table.

displays the next page of the table.

2

Select the

Delete

check box next to the row that contains the profile you want to delete. To

select the

Delete

check box for all rows (except the default profile, which cannot be

deleted), click

Check All

.

If you decide not to delete a selected row, clear the

Delete

check box next to the row. Click

Clear All

to clear the

Delete

check box for all rows.

3

Click

Delete Checked Row(s)

to delete the profiles.

A confirmation dialog displays.

4

Do one of the following:

Click

OK

to delete the selected table rows.

Click

Cancel

to not delete the table rows.

You cannot delete profiles that are assigned to ports.