Monitoring SONET Performance

520

Avidia System Configuration and Management User Manual

Line Type

The type of SONET line. The Avidia system currently supports
short-reach single-mode, multi-mode, and other SONET
lines.

Section Current Performance

Port

The port number for which the Section current performance is
displayed (each line card has two ports).

Status

Options:

sonetSectionNoDefect

There are no errors on the

SONET Section layer.

sonetSectionLOS

There is a Loss Of Signal on the

SONET Section layer.

sonetSectionLOF

There is a Loss Of Frame on the

SONET Section layer.

Errored Seconds

The number of seconds during which at least one Section layer
bipolar error was detected or a severely errored frame or loss
of signal error was present.

Severely Errored Seconds

The number of seconds during which 2,500 or more Section
layer bipolar errors were detected or a severely errored frame
or loss of signal error was present.

Severely Errored Framing
Seconds

The number of seconds during which a severely errored frame
error was present. A severely errored frame is detected when
the incoming signal has a minimum of four consecutive
errored framing patterns.

Coding Violation

A count of bipolar errors detected at the Section layer.

Information

Description