Configuring DS1 Service

420

Avidia System Configuration and Management User Manual

The

DS1 Configuration

window displays the following status information that cannot be

changed.

Information

Descriptions

Card Description
Slot
Port

The slot number, port number and description of the selected
card.

Oper Status

The current operational status of the selected port.

Up indicates the port is operational and passing data.

Down indicates that the port is not operational.

Elapsed Time

The number of seconds that have elapsed since the current
15-minute data collection period began.

Valid Intervals

The number of 15-minute data collection intervals supported.
The Avidia system supports 96 intervals, or 24 hours, of data
collection.

Invalid Intervals

The Avidia system does not have invalid intervals, therefore

0

displays.

Line Status

The status of the line interface. Options:

dsx1NoAlarm—No alarm is present.

dsx1RcvFarEndLOF—Remote loss of frame alarm.

dsx1RcvAIS—Remote AIS.

dsx1LossOfFrame—Local loss of frame alarm.

dsx1LossOfSignal—Local loss of signal alarm.

Last Line Status Change

The time at which the line entered its current status (see the
Line Status description above for a definition of line status).

Send Code

The type of data currently being transmitted. Currently, the only
data type supported is sending Looped or normal data.

Facilities Data Link

This parameter is not currently supported, therefore
dsx1FdlNone displays. Facilities Data Link is a protocol that
enables communication with the remote device when in ESF
mode.

Loopback Status

The type of physical layer loopback in effect. See

“Initiating

Communication Path Loopbacks” on page 563

for information

about loopbacks.