Chapter 20: Configuring Subscriber Services

Avidia System Configuration and Management User Manual

413

3

In the

Clock Source

box, select the transmit clock source for the IDSL card (

Local

,

System

A

,

or

System B

).

Local

—The IDSL card derives timing from the IDSL card clock.

System A

—The IDSL card derives timing from the Avidia system reference clock on

channel A.

System B

—The IDSL card derives timing from the Avidia system reference clock on

channel B.

4

In the

Line Profile

boxes, type the desired line profile index for each port you want to

configure.

Click the

Line Profile Browse

button

to display the configured profiles. If the desired profile

is not yet configured, you can configure it now. See

“Configuring IDSL Line Profiles” on

page 406

for instructions.

5

In the

Alarm Profile

boxes, type the desired alarm profile index for each port you want to

configure.

Click the

Alarm Profile Browse

button

to display the configured profiles. If the desired profile

is not yet configured, you can configure it now. See

“Configuring IDSL Alarm Profiles” on

page 408

for instructions.

6

In the

Circuit ID

boxes, enter the circuit identifier for the port.

The circuit ID is the transmission vendor’s circuit identifier for the port. This identifier,
which can facilitate troubleshooting, can be up to 255 characters.

7

Do one of the following:

Click

Set

to activate the new settings.

Click

Get

to cancel the new settings. You can only cancel the settings if you have not

clicked

Set

.

In the

Slot

box select the slot number to configure ports on another card.