Chapter 28: Monitoring System Alarms and Status

Avidia System Configuration and Management User Manual

553

The

SDSL Cell Alarm Status

window displays the alarm status for the current 15-minute data

collection interval. The current alarm status displays for both the

Network

(upstream) and

Customer

(downstream) traffic.

M

ONITORING

IDSL A

LARM

S

TATUS

The

IDSL Alarm Status

window displays a summary of the alarm data for a specified IDSL line

and port.

1

Do one of the following:

In the

Site Map Navigation

window, click

IDSL Alarm Status

.

In the

Tree Navigation

window, click

Alarm

,

IDSL Alarm Status

.

The

IDSL Alarm Status - Slot/Port Selection

window displays.

Information Description

Card Description
Slot
Port

The slot, port and description of the card for which
the alarm information is displayed.

Loss of Signal Seconds (LOSS)

Loss of signal seconds are seconds during which
the SDSL cell line is incapable of transmitting or
receiving data and all data is lost.

Loss of Cell Delineation (LOCD)

Loss of cell delineation seconds are seconds in
which some cells transmitted during that second
were lost

.

Severe Loss of Cell Delineation (SLOCD)

Severe loss of cell delineation seconds are seconds
in which the total number of LOCD events in that
second exceed 50% of the total bandwidth available
during that second. During a severe loss of cell
delineation second most of the cells transmitted
during that second are lost.

SNR

SNR margin is a measure of signal quality
indicating how much margin can be dropped before
the number of bit errors exceeds the ratio of 1x10-7
errored bits per bits transmitted

.

Last Time Alarm Status Changed