Monitoring system hardware status, Onitoring, Ystem – ADC AVIDIA SWD4573I1 User Manual

Page 365: Ardware, Tatus

Advertising
background image

Chapter 16: Monitoring System Alarms and Status

Avidia System Configuration and Management User Manual

339

M

ONITORING

S

YSTEM

H

ARDWARE

S

TATUS

You monitor system status information, such as fuse and power alarms, and whether a critical,
major or minor alarm condition exists. From the

::root=>

prompt, type the following

command then press

.

display hardware system

A screen similar to the following displays.

The following table describes the system status information that displays when you type the
display hardware system command.

Information

Description

Power

Chassis power supply status. Options:

Unknown

Unknown power supply status.

Failure

One or both power supplies has failed.

OK

Both power supplies are operational.

Fan

Chassis fan status. Options:

Unknown

Unknown fan status or no fans exist.

Failure

One of the fans has failed.

OK

All fans are operational.

Hightemp

The chassis temperature is higher than the range

required for operation.

CRT

Chassis critical alarm LED status. Indicates whether a critical alarm
condition exists. Displays either OFF or ON.

MAJ

Chassis major alarm LED status. Indicates whether a major alarm
condition exists. Displays either OFF or ON.

ENTER

::hardware=> system

Power Fan CRT MAJ MIN AUD FAN1 FAN2 FAN3 FAN4 PWR_MIN IP1

IP2

FU1

FU2

OK

OK

OFF OFF OFF ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

Port

Card Description

Most_Serious_Alarm

Severity

1

Avidia Management Card

PSFailureAlarm

Critical

Advertising